Kitchen & Laundry Room Pumps / Floor Standing Lifting StationsSanicom 2
Ambient visual of the Sanicom 2 lifting stations to be installed, for aggressive/saline/grey water installed in a laundry room.

Sanicom 2

The Sanicom 2 hot water lifting station is ideal for heavy use in a commercial premises.
Easy installation: station to be placed directly on the ground
Two low inlets on each side (diameter 40/50/80 mm)
2 pumps for intense and secure operation
Remote control box with manual override and alarm
Level alarm included.
Find out more

Product details

The Sanicom 2 is ideal for use in public or commercial environments. A powerful lifting pump that can handle waste water from a sink, washing machine, dishwasher, shower, bath, and bidet. The Sanicom 2 is a two-motor lifting pump, where the second motor is a failsafe backup. It has two inlets, and it discharges through 50 mm pipework. It has a working temperature of 35ºC, however, it can handle temperatures up to 90ºC for short periods. The Sanicom 2 has a tank capacity of 34 litres, and the unit operates automatically. The Sanicom 2 comes with an external hard-wired alarm for additional peace of mind. The Sanicom 2 comes with a 2-year warranty.

With 60 years of expertise and innovation, Sanicom 2 is designed, made, and tested in France.



The benefits of installing the Sanicom 2 are:
● It has two powerful motors, and the second motor acts as a failsafe backup

● It is a heavy-duty, safe, and reliable pump with a tank volume of 34 litres

● Pumps water up to 15 m vertically

● Can handle temperatures of up to 90ºC for short periods of time

● It comes equipped with a control panel and an alarm system



Application of Sanicom 2 grey water lifting pump:
● Small Commercial Spaces: Commercial kitchens, cafes, restaurants, bars, office buildings, hair salons, shopping centres, sports facilities, co-working space, laundromats, car washes, garages.

● Healthcare Facilities: Hospitals, clinics, laboratories, and nursing homes.

● Hospitality Industry: Hotels, resorts, bed and breakfasts, or guesthouses.

● Educational Institutions: Schools, colleges, or universities.



Why choose Sanicom 2?:
● No core cutting or pit digging: The floor-standing design of the pump ensures installation of the pump without the need for core cutting or pit digging.

● Two Powerful Motors: It has two powerful motors that operate alternatively and act as a fail-safe backup. Thanks to its robust grinding system, it can discharge wastewater in 50 mm pipe.

● Suitable for commercial environments: With a flow rate of 16 m3/hr, it can lift wastewater up to 15 m and can handle temperatures of up to 90ºC for short periods of time.

● Multiple Connections: This lifting station can take wastewater from multiple connections, such as a sink, washing machine, dishwasher, washbasin, bath, bidet, and shower.

● Easy maintenance: One can get direct access to the motor and electrical parts. Motors can be easily removed for servicing and easy maintenance.



Frequently asked questions (FAQs):
Q 1. What makes the Sanicom 2 different from the Sanicom 1?

A: The Sanicom 2 features two powerful motors, including a failsafe backup motor, ensuring continuous service in busy commercial environments.

Q 2. What types of connections is the Sanicom 2 suitable for?

A: The Sanicom 2 is suitable for multiple connections, including basins, baths, showers, bidets, sinks, dishwashers, and washing machines, making it versatile for various commercial applications.

Q 3. What are the key benefits of installing Sanicom 2?

A: The Sanicom 2 offers numerous benefits, including its heavy-duty and reliable performance, two powerful motors for added reliability, suitability for heavy commercial applications, and the ability to pump water vertically up to 15 meters.
Technical specification

Sanicom 2

Materials

  • Shaft
  • Tank
  • Pump housing
  • Seal
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Seal
  • Seal
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • 1.4021
  • Tank
  • PE
  • Pump housing
  • PA 12 GF
  • Seal
  • NBR
  • Motor housing
  • Aluminium
  • Impeller
  • PA 6 GF

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP rating
  • Electrical class
  • Motor insulation class
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Length (m)
  • Section (mm²)
  • Type of cable
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP rating
  • IP rating
  • Electrical class
  • Electrical class
  • Motor insulation class
  • Motor insulation class
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Length (m)
  • Length (m)
  • Section (mm²)
  • Section (mm²)
  • Type of cable
  • Type of cable
  • Number of motor(s)
  • Dual motor
  • Socket included
  • No
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 1500
  • Power output P2 (W)
  • 1050
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 6.5
  • IP rating
  • IPX4
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 2
  • Number of pumps
  • 2
  • Type of control box
  • Classic
  • Length (m)
  • 2,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G

Hydraulic

  • Max. Head. (m)
  • Max. flow rate. (m³/h)
  • Number of inlets
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Min. shower tray height (mm)
  • Type of impeller
  • Type of activation
  • Max. Head. (m)
  • Max. Head. (m)
  • Max. flow rate. (m³/h)
  • Max. flow rate. (m³/h)
  • Number of inlets
  • Number of inlets
  • External inlet diameter (mm)
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • ON Level (mm)
  • OFF level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Alarm level (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Min. shower tray height (mm)
  • Min. shower tray height (mm)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head. (m)
  • 15
  • Max. flow rate. (m³/h)
  • 18
  • Number of inlets
  • 2
  • External inlet diameter (mm)
  • 80, 40, 50
  • Discharge diameter ext. (mm)
  • 50
  • Ext. ventilation diameter (mm)
  • 50
  • Total volume (L)
  • 34
  • Useable volume (L)
  • 13
  • ON Level (mm)
  • 145
  • OFF level (mm)
  • 60
  • Alarm level (mm)
  • 215
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 90 °C
  • Min. shower tray height (mm)
  • 250
  • Type of impeller
  • Multi-channel
  • Type of activation
  • Pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 28

General description

  • EAN code
  • EAN code
  • EAN code
  • EAN code
  • 3308815082868
FAQs

Frequently Asked Questions

  • The Sanicom 2 is designed for hot grey water and aggressive wastewater. It can be used in commercial kitchens, laundries, dental practices, changing rooms and similar professional environments. It must not be connected to toilets or used for black water.

  • Yes. The Sanicom 2 is designed to handle wastewater temperatures of up to 90°C for short periods of up to 5 minutes. It is therefore suitable for applications that produce hot grey water, provided that the installation complies with the product instructions.

  • The Sanicom 2 has two independent pumps. The second pump can assist the first when the incoming wastewater flow is particularly high. This configuration supports intensive use and improves the operational security of the installation.

  • The Sanicom 2 is supplied with a remote control box, forced operation, a built-in level alarm and two integrated non-return valves. The control box is connected to the station by a 2-metre cable. A separate wired alarm box can also be added as an option.

  • The Sanicom 2 is designed for hot grey water and aggressive wastewater. It can be used in commercial kitchens, laundries, dental practices, changing rooms and similar professional environments. It must not be connected to toilets or used for black water.

  • The Sanicom 2 has two independent pumps. The second pump can assist the first when the incoming wastewater flow is particularly high. This configuration supports intensive use and improves the operational security of the installation.

  • Yes. The Sanicom 2 is designed to handle wastewater temperatures of up to 90°C for short periods of up to 5 minutes. It is therefore suitable for applications that produce hot grey water, provided that the installation complies with the product instructions.

  • The Sanicom 2 is supplied with a remote control box, forced operation, a built-in level alarm and two integrated non-return valves. The control box is connected to the station by a 2-metre cable. A separate wired alarm box can also be added as an option.

Quality

Buy with confidence

  • Made in France

    Many products have received the Made in France label.

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity.

  • Warranty

    Up to 2 years warranty.

  • Extensive support

    A network of repair technicians.

  • Experts Since 1958

    Creator of the Sanibroyeur macerating toilet.