Technical specification
Sanipump SLD 700
- Version
- Version
- Version
- Version
- Sanipump SLD 700 S
- Version
- Sanipump SLD 700 SA
- Version
- Sanipump SLD 700 T
Materials
- Shaft
- Pump housing
- Seal
- Foot
- Motor housing
- Impeller Use this glossary to ensure consistency:
- Shaft
- Shaft
- Pump housing
- Pump housing
- Seal
- Seal
- Foot
- Foot
- Motor housing
- Motor housing
- Impeller Use this glossary to ensure consistency:
- Impeller Use this glossary to ensure consistency:
- Shaft
- 1.4021
- Pump housing
- EN-GJL-200
- Seal
- Carbon/Ceramic/NBR
- Foot
- EN-GJL-200
- Motor housing
- EN-GJL-200
- Impeller Use this glossary to ensure consistency:
- EN-GJL-200
- Shaft
- 1.4021
- Pump housing
- EN-GJL-200
- Seal
- Carbon/Ceramic/NBR
- Foot
- EN-GJL-200
- Motor housing
- EN-GJL-200
- Impeller Use this glossary to ensure consistency:
- EN-GJL-200
- Shaft
- 1.4021
- Pump housing
- EN-GJL-200
- Seal
- Carbon/Ceramic/NBR
- Foot
- EN-GJL-200
- Motor housing
- EN-GJL-200
- Impeller Use this glossary to ensure consistency:
- EN-GJL-200
Electrical features
- Socket included
- Voltage (V)
- Frequency Use this glossary to ensure consistency: fr-FR en-GB Frequency Frequency (Hz)
- Power consumption P1 (W)
- Power output P2 (W)
- Revolution per minute (RPM)
- Maximum current (A)
- IP rating
- Electrical class
- Motor insulation class
- Submerged
- Immersion depth (m)
- Current Use this lexicon to ensure consistency :
- Length of cable-control box (m)
- Length (m)
- Section Use this glossary to ensure consistency : (mm²)
- Type of cable
- Socket included
- Socket included
- Voltage (V)
- Voltage (V)
- Frequency Use this glossary to ensure consistency: fr-FR en-GB Frequency Frequency (Hz)
- Frequency Use this glossary to ensure consistency: fr-FR en-GB Frequency Frequency (Hz)
- Power consumption P1 (W)
- Power consumption P1 (W)
- Power output P2 (W)
- Power output P2 (W)
- Revolution per minute (RPM)
- Revolution per minute (RPM)
- Maximum current (A)
- Maximum current (A)
- IP rating
- IP rating
- Electrical class
- Electrical class
- Motor insulation class
- Motor insulation class
- Submerged
- Submerged
- Immersion depth (m)
- Immersion depth (m)
- Current Use this lexicon to ensure consistency :
- Current Use this lexicon to ensure consistency :
- Length of cable-control box (m)
- Length of cable-control box (m)
- Length (m)
- Length (m)
- Section Use this glossary to ensure consistency : (mm²)
- Section Use this glossary to ensure consistency : (mm²)
- Type of cable
- Type of cable
- Socket included
- No
- Voltage (V)
- 230
- Frequency Use this glossary to ensure consistency: fr-FR en-GB Frequency Frequency (Hz)
- 50-60
- Power consumption P1 (W)
- 2000
- Power output P2 (W)
- 1100
- Revolution per minute (RPM)
- 2800
- Maximum current (A)
- 9.2
- IP rating
- IP68
- Electrical class
- I
- Motor insulation class
- F
- Submerged
- S1
- Immersion depth (m)
- 20
- Current Use this lexicon to ensure consistency :
- Single-phase
- Length of cable-control box (m)
- -
- Length (m)
- 10
- Section Use this glossary to ensure consistency : (mm²)
- 1.5
- Type of cable
- H07 RN8-F
- Socket included
- No
- Voltage (V)
- 230
- Frequency Use this glossary to ensure consistency: fr-FR en-GB Frequency Frequency (Hz)
- 50-60
- Power consumption P1 (W)
- 2000
- Power output P2 (W)
- 1100
- Revolution per minute (RPM)
- 2800
- Maximum current (A)
- 9.2
- IP rating
- IP68
- Electrical class
- I
- Motor insulation class
- F
- Submerged
- S1
- Immersion depth (m)
- 20
- Current Use this lexicon to ensure consistency :
- Single-phase
- Length of cable-control box (m)
- 10
- Length (m)
- 10
- Section Use this glossary to ensure consistency : (mm²)
- 1.5
- Type of cable
- H07 RN8-F
- Socket included
- No
- Voltage (V)
- 400
- Frequency Use this glossary to ensure consistency: fr-FR en-GB Frequency Frequency (Hz)
- 50-60
- Power consumption P1 (W)
- 2000
- Power output P2 (W)
- 1100
- Revolution per minute (RPM)
- 2800
- Maximum current (A)
- 3.3
- IP rating
- IP68
- Electrical class
- I
- Motor insulation class
- F
- Submerged
- S1
- Immersion depth (m)
- 20
- Current Use this lexicon to ensure consistency :
- Three-phase
- Length of cable-control box (m)
- -
- Length (m)
- 10
- Section Use this glossary to ensure consistency : (mm²)
- 1.5
- Type of cable
- H07 RN8-F
Hydraulic
- Max. Head. (m)
- Max. flow rate. (m³/h)
- Discharge diameter DN
- Discharge diameter G (inch)
- ON Level (mm)
- OFF level (mm)
- Particle size (mm)
- Max. temperature of the pumped liquid (5 min) (° C)
- Medium Use this glossary to ensure consistency: (°C)
- Type of impeller
- Type of activation
- Max. Head. (m)
- Max. Head. (m)
- Max. flow rate. (m³/h)
- Max. flow rate. (m³/h)
- Discharge diameter DN
- Discharge diameter DN
- Discharge diameter G (inch)
- Discharge diameter G (inch)
- ON Level (mm)
- ON Level (mm)
- OFF level (mm)
- OFF level (mm)
- Particle size (mm)
- Particle size (mm)
- Max. temperature of the pumped liquid (5 min) (° C)
- Max. temperature of the pumped liquid (5 min) (° C)
- Medium Use this glossary to ensure consistency: (°C)
- Medium Use this glossary to ensure consistency: (°C)
- Type of impeller
- Type of impeller
- Type of activation
- Type of activation
- Max. Head. (m)
- 14
- Max. flow rate. (m³/h)
- 48
- Discharge diameter DN
- 50
- Discharge diameter G (inch)
- 2
- ON Level (mm)
- -
- OFF level (mm)
- -
- Particle size (mm)
- 50
- Max. temperature of the pumped liquid (5 min) (° C)
- 40 °C
- Medium Use this glossary to ensure consistency: (°C)
- -
- Type of impeller
- Impeller two-channel
- Type of activation
- -
- Max. Head. (m)
- 14
- Max. flow rate. (m³/h)
- 48
- Discharge diameter DN
- 50
- Discharge diameter G (inch)
- 2
- ON Level (mm)
- 56cm
- OFF level (mm)
- 39cm
- Particle size (mm)
- 50
- Max. temperature of the pumped liquid (5 min) (° C)
- 40 °C
- Medium Use this glossary to ensure consistency: (°C)
- -
- Type of impeller
- Impeller two-channel
- Type of activation
- float
- Max. Head. (m)
- 14
- Max. flow rate. (m³/h)
- 48
- Discharge diameter DN
- 50
- Discharge diameter G (inch)
- 2
- ON Level (mm)
- -
- OFF level (mm)
- -
- Particle size (mm)
- 50
- Max. temperature of the pumped liquid (5 min) (° C)
- 40 °C
- Medium Use this glossary to ensure consistency: (°C)
- 40 °C
- Type of impeller
- Impeller two-channel
- Type of activation
- -
Logistics
- Gross weight (kg)
- Gross weight (kg)
- Gross weight (kg)
- Gross weight (kg)
- 32,5
- Gross weight (kg)
- 32,8
- Gross weight (kg)
- 31
General description
- EAN code
- EAN code
- EAN code
- EAN code
- 3308815084015
- EAN code
- 3308815083988
- EAN code
- 3308815084060
Quality
Buy with confidence
Made in France
Many products have received the Made in France label.
Performance and Reliability
Technologies and materials that ensure efficiency and longevity.
Warranty
Up to 2 years warranty.
Extensive support
A network of repair technicians.
Experts Since 1958
Creator of the Sanibroyeur macerating toilet.